- Home /
- Waterproofing Products /
- Dr Fixit Prices /
- Vertical Expansion Joint (boq)
Vertical Expansion Joint (BOQ)


Available sizes | Price |
---|
Product details | |
---|---|
Packaging Size: | |
Brand: | |
Usage surfaces: | Expansion joint |
Vertical Expansion Joint (BOQ)
Joint Preparation Clean the surfaces removing all loose materials, dirt, rust, lacquers, grease, bitumenand its traces, etc. complete. Joint should be cleaned mechanically like wire brushing, chiseling etc. It is also recommended to use compressed air / vacuum cleaner to clean up the grooves and remove dirt or any loose materials in the joints. Insert back up material or filler board made from polystyrene to required depth . Insert polystyrene rod as a bond breaker over back up material . Use masking tape on the both edges of the joint to have proper finish Priming Prime only on two sides of the properly prepared joint surface with Pidiprime A with a brush. Application Tansfer the entire quantity of accelerator/curing agent to the base and mix thoroughly with a slow speed electric mixer (300 to 450 RPM) for approximately 5-6 min or until a homogeneous, uniform grey colour material is obtained. Fill the joint with Dr. Fixit Pidiseal PS 41 G, Gun grade - self Levelling Polysulphide Sealant into the joint, which will self level on its own. Apply sealant in the prepared joint after the primer coat has cured for minimum 30 minutes and maintaining depth to width ratio of the joint as 1:2 (min) for a normal application. Note: The expansion joints which are exposed to mechanical / manual abuses must be protected with suitable Membrane or Metal Plate fixed at one end, taking precaution to enable the joints to move freely and meet the architectural requirements.
Features & Benefits
Corrosion resistant - Makes concrete more cohesive, hence protects steel better against corrosion.
Compatibility – Being a liquid, easily dispersible & compatible with concrete/mortar mixes.
Permeability – It reduces the permeability of water into concrete.
Strength – The setting time and compressive strength of the concrete remains within the specification limits.
Shrinkage – Reduces shrinkage crack development in plaster & concrete.
Workability – Improves workability of freshly mixed cement concrete.
Durability – Increases durability by improving waterproofing of concrete.
Product Process
Step 1
Surface Preparation Remove dust, laitance etc. by wire brush and broom. Clean the surface with water and make Surface Saturated Dry (SSD) condition. Check the surface moisture content and temperature before application of the coating.
Step 2
Dressing at Junctions Apply the first coat of Dr. Fixit material on the angle fillet. Place and soak 150 mm width of 45-micron open woven glass fiber mesh as reinforcement on the wet first coat to arrest cracking.
Step 3
Coating Application Apply
Waterproofing Products
Waterproofing FAQs
Q. How do I calculate waterproofing cost for Vertical Expansion Joint (BOQ)?We've developed WATERPROOFING COST CALCULATOR where you can calculate the tentative cost of waterproofing. |
Q. How do I apply Vertical Expansion Joint (BOQ)?Joint Preparation Clean the surfaces removing all loose materials, dirt, rust, lacquers, grease, bitumenand its traces, etc. complete. Joint should be cleaned mechanically like wire brushing, chiseling etc. It is also recommended to use compressed air / vacuum cleaner to clean up the grooves and remove dirt or any loose materials in the joints. Insert back up material or filler board made from polystyrene to required depth . Insert polystyrene rod as a bond breaker over back up material . Use masking tape on the both edges of the joint to have proper finish Priming Prime only on two sides of the properly prepared joint surface with Pidiprime A with a brush. Application Tansfer the entire quantity of accelerator/curing agent to the base and mix thoroughly with a slow speed electric mixer (300 to 450 RPM) for approximately 5-6 min or until a homogeneous, uniform grey colour material is obtained. Fill the joint with Dr. Fixit Pidiseal PS 41 G, Gun grade - self Levelling Polysulphide Sealant into the joint, which will self level on its own. Apply sealant in the prepared joint after the primer coat has cured for minimum 30 minutes and maintaining depth to width ratio of the joint as 1:2 (min) for a normal application. Note: The expansion joints which are exposed to mechanical / manual abuses must be protected with suitable Membrane or Metal Plate fixed at one end, taking precaution to enable the joints to move freely and meet the architectural requirements. |
Q. Do you provide any service warranty for Vertical Expansion Joint (BOQ)?There are two kinds of warranties involved in painting process. |
Q. In what variants and packaging price Vertical Expansion Joint (BOQ) Is available?Vertical Expansion Joint (BOQ) Is Available in different variant listed below. |
Q. Can I use Vertical Expansion Joint (BOQ) for Expansion joint leakage waterproofing?Yes, Vertical Expansion Joint (BOQ) can be used for Expansion joint leakage waterproofing |